Diaphragm wall construction begins with the trench being excavated in discontinuous sections or "panels". Stop end pipes are placed vertically at each end of the primary panel to form joints for adjacent secondary panels. Panels are usually 8 to 20 feet long with widths varying from 2 to 5 feet. Once the excavation of a panel is complete, a steel reinforcement cage is placed in the center of the panel. Concrete is poured in one continuous operation through one or more tremie pipes that extend to the bottom of the trench. The tremie pipes are extracted as the concrete rises; however, the discharge end of the tremie pipe always remains embedded in the fresh concrete. The slurry that is displaced by the concrete is saved and reused for subsequent panel excavations. When the concrete sets, the end pipes are withdrawn. Similarly, secondary panels are constructed between the primary panels to create a continuous wall. The finished wall may be cantilever or require anchors/props for lateral support. A variation of the technique is the precast diaphragm wall. With this method a continuous trench, or longer panel, is excavated under self-hardening cement bentonite slurry. The slurry is retarded to remain fluid during construction. After a sufficient length of excavation is complete, a crane lifts the precast concrete wall section into the trench. The cement bentonite slurry sets to form the final composite wall. Alternately, the trench is excavated under bentonite slurry, which is then displaced with cement bentonite slurry. Diaphragm wall is commonly used in congested areas. They can be installed in close proximity to existing structures with minimal loss of support to existing foundations. In addition, construction dewatering is not required, so there is no associated subsidence. The cut and cover method is used to construct tunnels. Two parallel diaphragm walls are installed and the area between the walls is excavated. Floor and roof slabs are poured and the area above the roof is backfilled. For additional information on diaphragm walls, visit www.diaphragmwall.com. |
![]() |
||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||
Home | Services | Slurry Walls | Diaphragm Wall | Soil Mixing | Jet Grouting | Remediation | Permeable Reactive Barrier | Experience | Safety | Contact Us | Site Map © Recon 2004 - 2008 | Website Design by eNet Technologies |
||||||||||||||||||||||||||||||||||||||||